Size: 249
Comment:
|
← Revision 13 as of 2016-05-04 22:09:50 ⇥
Size: 3426
Comment: converted to 1.6 markup
|
Deletions are marked like this. | Additions are marked like this. |
Line 5: | Line 5: |
[[TableOfContents]] | <<TableOfContents>> |
Line 7: | Line 7: |
= Synopsis = | == Synopsis == |
Line 9: | Line 9: |
== Use Case == | The overall goal of this case study is to provide the utility of Open Knee(s) - Generation 1 model for reproducing the outcome of a clinical test, the pivot shift, for evaluating mechanical function of the anterior cruciate ligament. |
Line 11: | Line 11: |
== Simulation Aims == | === Use Case === |
Line 13: | Line 13: |
== Model == | The case is based on reproduction of a pivot shift loading scenario in a tibiofemoral joint model. The loading scenario was measured in a cadaver knee during pivot shift tests conducted by an orthopaedic surgeon. In follow-up robotics testing, this loading profile was adjusted for robotics testing of intact, ACL deficient, and ACL reconstructed knees. The use case aims for illustrating the capacity of the Open Knee(s) - Generation 1 model to reproduce the clinical differentiation of intact and ACL deficient knee in a virtual sense. |
Line 15: | Line 15: |
== Inputs == | === Simulation Aims === |
Line 17: | Line 17: |
== Outputs == | * To understand the role of ACL for stabilization of the joint during pivot shift testing (primary) * To explore the correspondence of Open Knee(s) simulation against robotics prescribed pivot shift loading of various knees (secondary) |
Line 19: | Line 20: |
== Simulation Conditions == | === Model === |
Line 21: | Line 22: |
= Team Members = | The model is based on Open Knee(s) - Generation 1 model, which was updated for FEBio version 2.1: |
Line 23: | Line 24: |
= Progress = | . https://simtk.org/svn/openknee/_gen1/src/tf_joint_FEBio_v2.feb === Inputs === Prescribed time histories of movement and loading of the tibiofemoral joint (six degrees of freedom) representative of pivot shift data: * flexion * internal/external rotation torque * varus/valgus torque * anterior/posterior force * medial/lateral force * compression/distraction force === Outputs === * Time histories of kinematics-kinetics of the tibiofemoral joint (six degrees of freedom) (primary) * flexion torque * internal/external rotation * varus/valgus * anterior/posterior translation * medial/lateral translation * compression/distraction * Time histories of stress-strain behavior (secondary) === Simulation Conditions === * with intact ACL * without the ACL (very low stiffness for convenient modeling and simulation workflow) == Team Members == * Ahmet Erdemir - study planning, outline of publications * Snehal Chokhandre - execution of simulations and post-processing, lead authorship in publications * Craig Bennetts - assisting simulations, scripting for pre-/post-processing, support to document model in publications * Tara Bonner - assiting pivot shift trajectory generation, support documentation on pivot shift literature and implications of simulations for robotics testing * Robb Colbrunn - lead pivot shift trajectory generation, provide literature survey on pivot shift studies (clinical and cadaver testing), support to document implications of simulations for robotics testing * Paul Saluan - support to document clinical utility of pivot shift and implications of simulations for clinical practice == Progress == === Source Code Repository === https://simtk.org/svn/openknee/app/PivotShift/ === Data === https://simtk.org/svn/openknee/app/PivotShift/dat/ === Model Customization === https://simtk.org/svn/openknee/app/PivotShift/src/ === Simulations === === Post-Processing === https://simtk.org/svn/openknee/app/PivotShift/sol/ === Publications === https://simtk.org/svn/openknee/app/PivotShift/doc/ == References == |
Contents
Synopsis
The overall goal of this case study is to provide the utility of Open Knee(s) - Generation 1 model for reproducing the outcome of a clinical test, the pivot shift, for evaluating mechanical function of the anterior cruciate ligament.
Use Case
The case is based on reproduction of a pivot shift loading scenario in a tibiofemoral joint model. The loading scenario was measured in a cadaver knee during pivot shift tests conducted by an orthopaedic surgeon. In follow-up robotics testing, this loading profile was adjusted for robotics testing of intact, ACL deficient, and ACL reconstructed knees. The use case aims for illustrating the capacity of the Open Knee(s) - Generation 1 model to reproduce the clinical differentiation of intact and ACL deficient knee in a virtual sense.
Simulation Aims
- To understand the role of ACL for stabilization of the joint during pivot shift testing (primary)
- To explore the correspondence of Open Knee(s) simulation against robotics prescribed pivot shift loading of various knees (secondary)
Model
The model is based on Open Knee(s) - Generation 1 model, which was updated for FEBio version 2.1:
Inputs
Prescribed time histories of movement and loading of the tibiofemoral joint (six degrees of freedom) representative of pivot shift data:
- flexion
- internal/external rotation torque
- varus/valgus torque
- anterior/posterior force
- medial/lateral force
- compression/distraction force
Outputs
- Time histories of kinematics-kinetics of the tibiofemoral joint (six degrees of freedom) (primary)
- flexion torque
- internal/external rotation
- varus/valgus
- anterior/posterior translation
- medial/lateral translation
- compression/distraction
- Time histories of stress-strain behavior (secondary)
Simulation Conditions
- with intact ACL
- without the ACL (very low stiffness for convenient modeling and simulation workflow)
Team Members
- Ahmet Erdemir - study planning, outline of publications
- Snehal Chokhandre - execution of simulations and post-processing, lead authorship in publications
- Craig Bennetts - assisting simulations, scripting for pre-/post-processing, support to document model in publications
- Tara Bonner - assiting pivot shift trajectory generation, support documentation on pivot shift literature and implications of simulations for robotics testing
- Robb Colbrunn - lead pivot shift trajectory generation, provide literature survey on pivot shift studies (clinical and cadaver testing), support to document implications of simulations for robotics testing
- Paul Saluan - support to document clinical utility of pivot shift and implications of simulations for clinical practice
Progress
Source Code Repository
https://simtk.org/svn/openknee/app/PivotShift/
Data
https://simtk.org/svn/openknee/app/PivotShift/dat/
Model Customization
https://simtk.org/svn/openknee/app/PivotShift/src/
Simulations
Post-Processing
https://simtk.org/svn/openknee/app/PivotShift/sol/
Publications
https://simtk.org/svn/openknee/app/PivotShift/doc/