Size: 1315
Comment:
|
← Revision 6 as of 2016-05-04 22:09:51 ⇥
Size: 1273
Comment: converted to 1.6 markup
|
Deletions are marked like this. | Additions are marked like this. |
Line 5: | Line 5: |
[[TableOfContents]] | <<TableOfContents>> |
Line 9: | Line 9: |
Following is the information about the institution where magnetic resonance imaging (MRI) will be collected, the associated contacts, and the specific MRI hardware that will be used. | Following is information about the institution where magnetic resonance imaging (MRI) will be collected, associated contacts, and the specific MRI hardware that will be used. |
Line 15: | Line 15: |
'''Institution:''' University Hospitals, Case Medical Center | '''Institution:''' University Hospitals, Case Western Reserve University |
Line 17: | Line 17: |
'''Principal Contact:''' Chris Flask, PhD, Assistant Professor, Radiology | '''Principal Contact:''' Chris Flask, PhD, Assistant Professor, Department of Radiology |
Line 19: | Line 19: |
Address:<<BR>> Bolwell B115<<BR>> 11100 Euclid Ave.<<BR>> Cleveland, OH 44106<<BR>> |
''Address'': <<BR>> Bolwell B115 <<BR>> 11100 Euclid Ave. <<BR>> Cleveland, OH 44106 |
Line 24: | Line 24: |
Email: chris.flask@uhhospitals.org<<BR>> Phone: 216-844-4963<<BR>> Fax: 216-844-4987<<BR>> |
''Email'': chris.flask@uhhospitals.org <<BR>> ''Phone'': 216-844-4963 <<BR>> ''Fax'': 216-844-4987 |
Line 28: | Line 28: |
'''MRI Technician:''' -- ["craigbennetts"] [[DateTime(2014-01-21T18:51:18Z)]] Jason, pop in what's-her-names info here. |
'''MRI Technician:''' Shannon Donnola, sbd39@case.edu |
Line 41: | Line 39: |
* https://usa.healthcare.siemens.com/magnetic-resonance-imaging/options-and-upgrades/coils/tx-rx-cp-extremity-coil | |
Line 46: | Line 43: |
* https://usa.healthcare.siemens.com/magnetic-resonance-imaging/options-and-upgrades/coils/tx-rx-cp-extremity-coil |
Contents
Overview
Following is information about the institution where magnetic resonance imaging (MRI) will be collected, associated contacts, and the specific MRI hardware that will be used.
Imaging Facility
Institution: University Hospitals, Case Western Reserve University
Principal Contact: Chris Flask, PhD, Assistant Professor, Department of Radiology
Address:
Bolwell B115
11100 Euclid Ave.
Cleveland, OH 44106
Email: chris.flask@uhhospitals.org
Phone: 216-844-4963
Fax: 216-844-4987
MRI Technician: Shannon Donnola, sbd39@case.edu
MRI System
Machine: Siemens MAGNETOM Skyra 3T, Clinical
Specifications:
http://radiology.case.edu/Facilities/ClinicalSystemsforResearch.aspx
http://usa.healthcare.siemens.com/magnetic-resonance-imaging/3t-mri-scanner/magnetom-verio
Receiver Coil: knee coil
Coil dimensions:
Length of inner bore: 256 mm (= 10.07" > 10,1/16")
Minimum inner diameter: 154 mm (= 6.06" > 6,1/32")