Recurring Meeting of Cleveland Clinic - University of Utah
Date: December 20, 2013
Time: 3.00 PM EST
Means: Conference call
Attendees:
- Ahmet Erdemir (Cleveland Clinic)
- Jason Halloran (Cleveland Clinic)
- Snehal Chokhandre (Cleveland Clinic)
- Jeff Weiss (University of Utah)
- Steve Maas (University of Utah)
- Ben Ellis (University of Utah)
Agenda:
1. Discuss assigned task progress. 2. Discuss implementation of In-situ strain test problem.
3. Decide tasks for next meeting. 4. Other
Notes:
- Discussed assigned task progress.
- Steve implemented the in-situ strain test problem in FEBIo.
- A two-step analysis was set up.
- In the first step in-situ stretch is applied (for different levels of stretch)
- In the next step a saw tooth prescribed displacement was applied on the free end of the beam (geometry : 1 by 10 mm mesh) and the stress-displacement curves were provided.
- Ahmet made an observation regarding the constitutive model (stress is not zeroed in the model). This will be fixed/implemted by the Utah team.
- A new version of FEBio will be released in January 2014.
- Steve implemented the in-situ strain test problem in FEBIo.