Line 40: Line 40:
===== Proposed tissue sample and data labeling convetion =====


 1. Expected samples:

  * Cartilage
   * Test type: Confined compression
   * Sample location:
     * Femur, medial
     * Femur, lateral
     * Tibia, medial
     * Tibia, lateral
     * Patella
  * Meniscus
   * Test type: Confined compression, Uniaxial tension
   * Sample location:
     * medial
     * lateral
  * Ligaments (Anetrior and posterior cruciate ligaments, medial and lateral collateral ligaments, and patellar ligament)
    * Test type: Uniaxial tension
    * Sample location: Mid-substance
  * Tendon (Quadricep)
    * Test type: Uniaxial tension
    * Sample location: Mid-substance

 2. Minimum number of samples: 15

  * Compression: 7 (1 patella, 4 cartilage, 2 meniscus)
  * Tension: 8 (5 ligaments, 2 meniscus, 1 tendon)

 
 3. Tissue Sample/data labels:

Note: Trial number will appear only for data files.


Labeling convention: specimen identifier - tissue type and orientation/ location identifier - test type identifier - trial number/ sample number identifier

 * Cartilage:
  * OK_ _-FECM-_-_ _ (medial femoral cartilage)
  * OK_ _-FECL-_-_ _ (lateral femoral cartilage)
  * OK_ _-PAC_-_-_ _ (Patellar cartilage)
  * OK_ _-TICM-_-_ _(medial tibial cartilage)
  * OK_ _-TICL-_-_ _(lateral tibial cartilage)


 * Meniscus:
  * OK_ _-MME(A/P/M)-_-_ _ (Location identifiers : A (anterior), P (posterior), M (middle))
  * OK_ _-LME(A/P/M)-_-_ _


 * Tendon:
  * OK_ _-QAT(S/M/I)-_-_ _ (Location identifiers : S (Superior), M (mid-substance), M (Inferior))

TableOfContents()

Overview

Open Knee(s) project will generate a plethora of heterogeneous data sets, e.g. DICOM images, joint/tissue mechanical testing data, etc. It is unnecessary and sometimes clumsy to put the data into source code repositories. The workflow of the "Downloads" section at the project site also seems cumbersome for intermediate storage of data, which may not be release ready. This specification is targeted to find a solution for online storage of data (in-house or at Open Knee(s) project site) that will accommodate the workflow of data collection, analysis, and public release. A separate project site at SimTK.org is available to expand management of data and relevant information for biomechanics studies beyond the realm of Open Knee(s), see https://simtk.org/home/dmmb.

Target Outcome

Storage of data for future discoverability, retrieval, and dissemination

Prerequisites

Previous Protocols

Any experimentation protocol, see

  • ["Specifications/ExperimentationAnatomicalImaging"]
  • ["Specifications/ExperimentationJointMechanics"]
  • ["Specifications/ExperimentationTissueMechanics"]

Protocols

Input

Procedures

-- ["aerdemir"] DateTime(2014-02-11T13:05:40Z) This section may list general purpose procedures and alternatives to utilize the same input to reach the same output. Procedures optimized for specific experimentation protocols should also be provided in here.

Labeling conventions

Tissue samples and data

Proposed tissue sample and data labeling convetion
  1. Expected samples:
    • Cartilage
      • Test type: Confined compression
      • Sample location:
        • Femur, medial
        • Femur, lateral
        • Tibia, medial
        • Tibia, lateral
        • Patella
    • Meniscus
      • Test type: Confined compression, Uniaxial tension
      • Sample location:
        • medial
        • lateral
    • Ligaments (Anetrior and posterior cruciate ligaments, medial and lateral collateral ligaments, and patellar ligament)
      • Test type: Uniaxial tension
      • Sample location: Mid-substance
    • Tendon (Quadricep)
      • Test type: Uniaxial tension
      • Sample location: Mid-substance
  2. Minimum number of samples: 15
    • Compression: 7 (1 patella, 4 cartilage, 2 meniscus)
    • Tension: 8 (5 ligaments, 2 meniscus, 1 tendon)
  3. Tissue Sample/data labels:

Note: Trial number will appear only for data files.

Labeling convention: specimen identifier - tissue type and orientation/ location identifier - test type identifier - trial number/ sample number identifier

  • Cartilage:
    • OK_ _-FECM-_-_ _ (medial femoral cartilage)
    • OK_ _-FECL-_-_ _ (lateral femoral cartilage)
    • OK_ _-PAC_-_-_ _ (Patellar cartilage)
    • OK_ _-TICM-_-_ _(medial tibial cartilage)
    • OK_ _-TICL-_-_ _(lateral tibial cartilage)
  • Meniscus:
    • OK_ _-MME(A/P/M)-_-_ _ (Location identifiers : A (anterior), P (posterior), M (middle))
    • OK_ _-LME(A/P/M)-_-_ _
  • Tendon:
    • OK_ _-QAT(S/M/I)-_-_ _ (Location identifiers : S (Superior), M (mid-substance), M (Inferior))