Size: 4036
Comment:
|
Size: 4227
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 54: | Line 54: |
* Figure 1: Data file hierarchy of tdms file | * Data file hierarchy of tdms file |
Line 58: | Line 58: |
* Figure 2 indicates raw desired kinetics and processed desired kinetics. | * Raw desired kinetics and processed desired kinetics shown below. attachment:Kinetics.JCS.Desired.png attachment:Kinetics.JCS.Desired_Processed.png |
Line 60: | Line 63: |
* Figures 3 and 4 show examples of processed kinematic and kinetic data. | * Examples of processed kinematic and kinetic data. attachment:State.JCS%20Load_Processed.png attachment:State.Knee%20JCS_Processed.png |
Line 86: | Line 91: |
attachment:RMSD_Repro_Table.txt |
Target Outcome
Loading and boundary conditions (kinematics-kinetics) reflecting experimentation, which are represented in model coordinate systems
- Access data in tdms file from tibiofemoral joint experimentation
- Process kinematic and kinetic data
Input & validation data for FE model
- Analyze reproducibility data (anterior-posterior laxity)
Prerequisites
Previous Protocols
- ["Specifications/ExperimentationAnatomicalImaging"]
- ["Specifications/ExperimentationJointMechanics"]
- ["Specifications/Registration"]
Protocols
Input
- Model coordinate systems and transformation matrices (obtained from imaging)
- Experimentation coordinate systems and transformation matrices (obtained from joint mechanics testing)
- Transformation matrices for registration of imaging and joint testing coordinate systems (obtained from registration)
Access script from source code repository: https://simtk.org/websvn/wsvn/openknee/utl/SimVitro/#_utl_SimVitro_
Script: tdms_plotting.py
- Processing data (use script tdms_plotting.py):
- Tdms files (Main Processed Data File)
- Filename: Experiment Run Number_Experiment Run Name + “_Main” + “_Processed”
- File extension: “.tdms”
- File Format: binary
- File Type: NI TDMS
- Text file with paths to tdms files within (include extension)
- Tdms files (Main Processed Data File)
Reproducibility data (use script tdms_plotting.py):
- Data from three AP laxity tests at 30 degree flexion
- Text file with path to the three tdms file within (include extension)
Procedures
- Use nptdms module to access data
- Data file hierarchy of tdms file
- Processing data:
- Find "time windows" during desired kinetics (Channel: Kinetics.JCS.Desired). "Time windows" are periods of time in which a constant force or torque is applied.
- Raw desired kinetics and processed desired kinetics shown below.
- attachment:Kinetics.JCS.Desired.png attachment:Kinetics.JCS.Desired_Processed.png
- Raw desired kinetics and processed desired kinetics shown below.
- Use "time windows" to process actual kinetics (Channel: State.JCS Load) and actual kinematics (Channel: State.Knee JCS).
- Examples of processed kinematic and kinetic data.
- attachment:State.JCS%20Load_Processed.png attachment:State.Knee%20JCS_Processed.png
- Examples of processed kinematic and kinetic data.
- Find "time windows" during desired kinetics (Channel: Kinetics.JCS.Desired). "Time windows" are periods of time in which a constant force or torque is applied.
- Reproducibility testing:
- Process kinematic/kinetic data from AP laxity 30 degrees flexion tests
- Enter '1' when prompted to run analysis for reproducibility testing (tdms_plotting.py)
- Compare differences between all combinations of the three reproducibility tests using RMSD
Compare tests 1 & 2, 1 & 3, 2 & 3
- Process kinematic/kinetic data from AP laxity 30 degrees flexion tests
Output
- Joint kinematics-kinetics information
- Experimental kinematics and/or kinetics described in a form that can be directly applied to the model as inputs.
- Experimental kinematics and/or kinetics described in a form that can be directly compared to the model outputs.
Processed kinematic & kinetic data
- Folder with tdms file name with directory of tdms files
- Plots of all raw data (path/filename/group.[png/svg])
- Plots of processed kinematic/kinetic data (path/filename/group_processed.[png/svg])
- Text file with processed kinematic/kinetic data (path/filename/group.txt)
- Reproducibility testing
- Folder titled Repro_filename with directory of tdms files (filename = 1st reproducibility tdms file)
- Plots comparing forces/torques and rotations/translations between tests (path/Repro_filename/group_forces.[png/svg])
- Text file with processed kinematic/kinetic data (path/Repro_filename/group_Data_Repro.txt)
- Text file with RMSD values (path/Repro_filename/RMSD_Repro_Table.txt)
- attachment:RMSD_Repro_Table.txt
Test Problem
-- ["aerdemir"] DateTime(2014-11-18T13:58:01Z) Reproducibility tests (30 degrees flexion anterior-posterior laxity) during characterization of tibiofemoral joint kinematics/kinetics can be a good candidate.