This page provides specifications of knee specimen '''OKS010'''. This was a pilot specimen and only imaging data is available. Courtesy of Todd Pataky and Grant 17H02151 from the Japan Society for the Promotion of Science. <<TableOfContents>> == Specimen Characteristics == Pilot knee Demographic information not available '''Gender:''' '' '' '''Age:''' '''Race:''' '' '' '''Height:''' '' '' '''Weight:''' '''BMI:''' '''Serologically tested:''' ''' X-ray: ''' Not available == Experimentation == === Specimen === '''Reference Specification:''' [[Specifications/Specimens]] - [[http://wiki.simtk.org/openknee/Specifications/Specimens?action=recall&rev=42|Revision as of FEb 4, 2019]] '''Leading Team Member:''' Tara Nagle '''Supporting Team Members:''' '''Timeline:''' '''Data Location:''' Specimen characteristics are provided in this wiki page. '''Protocol Deviations:''' 1. X-ray evaluation was not possible due to lack of X-ray imaging of the specimen. '''Notes:''' 1. None. === Specimen Preparation === '''Reference Specification:''' [[Specifications/SpecimenPreparation]] - [[http://wiki.simtk.org/openknee/Specifications/SpecimenPreparation?action=recall&rev=164|Revision as of Feb 4, 2019]] '''Leading Team Member:''' Tara Bonner '''Supporting Team Members:''' Robb Colbrunn, Callan Gillespie '''Timeline:''' '''Data Location:''' Data will be available as part of tibiofemoral joint mechanics data (see below). '''Protocol Deviations:''' 1. None. '''Notes:''' === Joint Imaging === ==== Specimen Preparation ==== '''Reference Specification:''' [[Specifications/SpecimenPreparation]] - [[http://wiki.simtk.org/openknee/Specifications/SpecimenPreparation?action=recall&rev=164|Revision as of Feb 4, 2019]] '''Leading Team Member:''' Tara Nagle '''Supporting Team Members:''' '''Timeline:''' '''Data Location:''' '''Protocol Deviations:''' 1. Patella marker was not attached. 1. CT was also acquired for the specimen. '''Notes:''' ==== Imaging ==== '''Reference Specification:''' [[Specifications/ExperimentationAnatomicalImaging]] - [[http://wiki.simtk.org/openknee/Specifications/ExperimentationAnatomicalImaging?action=recall&rev=121|Revision as of Feb 04, 2019]] '''Leading Team Member:''' Tara Nagle '''Supporting Team Members:''' '''Timeline:''' '''Data Location:''' Data was received from the imaging facilities and uploaded to in-house data management server (http://cobicore.lerner.ccf.org/midas; only accessible within Cleveland Clinic network). Raw DICOM files were stored in the folder Open Knee(s) --> Private --> oks010 --> MRI --> DICOM DICOM files were converted to NIfTI files, stored in the folder Open Knee(s) --> Private --> oks010 --> MRI --> NIFTI of the in-house data management server. Data storage was accomplished based on the updated imaging specifications, see [[http://wiki.simtk.org/openknee/Specifications/ExperimentationAnatomicalImaging?action=recall&rev=121|Revision as of Feb 4, 2019]]. '''Protocol Deviations:''' 1. None. '''Notes:''' 1. General purpose imaging 1. Cartilage imaging 1. Connective-tissue imaging === Joint Mechanics === ==== Specimen Preparation ==== '''Reference Specification:''' [[Specifications/SpecimenPreparation]] - [[http://wiki.simtk.org/openknee/Specifications/SpecimenPreparation?action=recall&rev=164|Revision as of Feb 4, 2019]] '''Leading Team Member:''' Tara Bonner '''Supporting Team Members:''' Robb Colbrunn, Callan Gillespie '''Timeline:''' '''Data Location:''' '''Protocol Deviations:''' 1. None. '''Notes:''' ==== Testing ==== '''Reference Specification:''' '''Leading Team Member:''' Tara Bonner, Robb Colbrunn '''Supporting Team Members:''' Callan Gillespie '''Timeline:''' '''Data Location:''' Data was received from the robotics testing facility and uploaded to in-house data management server (http://cobicore.lerner.ccf.org/midas; only accessible within Cleveland Clinic network). Zipped folders were stored in the folder Open Knee(s) --> Private --> oks010 --> !JointMechanics under relevant joint related folders. Zipped folders were extracted and organized in the dissemination folder under Open Knee(s) --> Private --> oks010 --> !JointMechanics --> DISSEMINATION of the in-house data management server. Data storage was accomplished based on the updated joint mechanics testing specifications, see [[http://wiki.simtk.org/openknee/Specifications/ExperimentationJointMechanics?action=recall&rev=102|Revision as of Feb 4, 2019]]. '''Protocol Deviations:''' 1. No patellofemoral joint testing is performed. 1. Tibiofemoral joint testing protocols were not followed as per specifications. '''Notes:''' === Tissue Mechanics === ==== Specimen Preparation ==== '''Leading Team Member:''' '''Supporting Team Members:''' '''Timeline:''' '''Data Location:''' '''Protocol Deviations:''' 1. '''Notes:''' ==== Testing ==== '''Reference Specification:''' '''Leading Team Member:''' '''Supporting Team Members:''' '''Timeline:''' '''Data Location:''' '''Protocol Deviations:''' 1. '''Notes:''' 1. == Data Analysis == == Modeling & Simulation ==