Search found 4 matches
- Fri Apr 02, 2021 11:43 am
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: 1D Modeling VTK Export Option
- Replies: 8
- Views: 335
Re: 1D Modeling VTK Export Option
Thanks Martin, It worked. I have another question regarding the exportation of the 1D modeling outputs as .VTK files. Currently, if we set to export the data files as .VTK file, SimVascular maps the flow variables on the straight tubes. In other words, it maps the 1D simulation outputs on an arteria...
- Tue Oct 13, 2020 12:50 pm
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: Time dependent outlet boundary condition
- Replies: 7
- Views: 180
Re: Time dependent outlet boundary condition
Hi Dave,
Great. I got. thanks
Sohrab
Great. I got. thanks
Sohrab
- Wed Oct 07, 2020 1:34 pm
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: Time dependent outlet boundary condition
- Replies: 7
- Views: 180
Re: Time dependent outlet boundary condition
Great. Thanks so much Dave
- Wed May 27, 2020 11:59 am
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: Error generating Mesh
- Replies: 20
- Views: 944
Re: Error generating Mesh
Dear Dave, Thanks for your response. I actually could resolve the issue and could successfully run the 1D simulation on my network (with constant cross sectional areas, like the warning messages). When I compare the time series of flow rate out of the simulation with our MRI data, I found pretty goo...