Search found 18 matches
- Wed Feb 27, 2019 12:24 am
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: Pressure inlet condition
- Replies: 4
- Views: 1043
Re: Pressure inlet condition
Thanks a lot for this comprehensive explanation! I'll start with the example you provided and work from there, see if it gets me where I want to go.
- Mon Feb 25, 2019 1:49 am
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: Pressure inlet condition
- Replies: 4
- Views: 1043
Pressure inlet condition
Hello all,
Is it possible in SimVascular to use a pressure waveform instead of a flow rate waveform as an inlet condition? I couldn't find anything on this in the documentation or on the forum.
Thanks in advance for your help,
Sita
Is it possible in SimVascular to use a pressure waveform instead of a flow rate waveform as an inlet condition? I couldn't find anything on this in the documentation or on the forum.
Thanks in advance for your help,
Sita
- Mon Feb 11, 2019 11:15 pm
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: Mass conservation
- Replies: 3
- Views: 469
Re: Mass conservation
Thanks a lot, that's really helpful!
Sita
Sita
- Mon Feb 11, 2019 11:17 am
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: Mass conservation
- Replies: 3
- Views: 469
Re: Mass conservation
In the meantime I've been experimenting with this Residual Criteria parameter, which does seem to help improving mass conservation. I was wondering, how is the residual norm defined here? And apart from reducing the value of Residual Criteria, would it also help to increase those Maximum Number of I...
- Fri Feb 08, 2019 11:33 am
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: Mass conservation
- Replies: 3
- Views: 469
Mass conservation
Hello all, After running the Coronary Normal demo project, I noticed that the flow rates in all_results-flows.txt and all_results-averages.txt don't add up to zero. There's a net flow rate of a few ml/s, which is only about 1% of the flow rate in the aorta, but it's considerable compared to the flow...
- Fri Feb 08, 2019 11:23 am
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: Error running job
- Replies: 6
- Views: 1958
Re: Error running job
Hi Dave,
Thanks, I'll give that a try.
Sita
Thanks, I'll give that a try.
Sita
- Thu Feb 07, 2019 8:53 am
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: Error running job
- Replies: 6
- Views: 1958
Re: Error running job
Hi all, It seems I'm having a similar problem: sometimes when starting a job with mpiexec I get this error: /usr/local/sv/svsolver/2019-01-19/svsolver: line 58: 60089 Segmentation fault: 11 $SV_HOME/bin/svsolver $* So it's only the "segmentation fault" bit, not the missing files. Without mpi, on a s...
- Tue Feb 05, 2019 4:19 am
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: Mapping of results onto different mesh
- Replies: 5
- Views: 1013
Re: Mapping of results onto different mesh
Awesome, thanks a lot, I'll try that!
- Mon Feb 04, 2019 8:52 am
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: Mapping of results onto different mesh
- Replies: 5
- Views: 1013
Re: Mapping of results onto different mesh
Sorry, just a follow-up question: if I use this Resample with Dataset filter in ParaView to map pressure/velocity results from one mesh onto another, is there any way to convert the results back into a restart-file for SimVascular? I'd like to use something like this to be able to use the end-result...
- Fri Feb 01, 2019 12:12 am
- Forum: SimVascular: Cardiovascular Modeling and Simulation Application
- Topic: Mapping of results onto different mesh
- Replies: 5
- Views: 1013
Re: Mapping of results onto different mesh
Hi Dave,
Great, thanks, I'll give that a try!
Sita
Great, thanks, I'll give that a try!