Hello,
I thought the time step during RRA is constant (typically 0.001). However, I incidentally found an RRA output where time step were not constant during the analysis:
time
...
0.48
0.4808624
0.481
0.4818624
0.482
0.4828624
0.483
0.4838624
0.484
0.485
...
I would be grateful if someone could tell me why this kind of thing happens.
Best regards,
Yusuke Okita
Irregular time step in RRA output
Re: Irregular time step in RRA output
The controls computations are performed and then updated every control time window (e.g. 0.001) which is a periodic event. The integrator is variable step and more (e.g. intermediate) steps can be necessary to achieve the desired accuracy.
- Yusuke Okita
- Posts: 44
- Joined: Sun Nov 21, 2010 11:25 pm
Re: Irregular time step in RRA output
Thank you for the reply. Then I will check if there's any problem about the tracking accuracy just in case.
Best regards,
Yusuke Okita
Best regards,
Yusuke Okita