Post by Chiho Ng » Wed Jul 27, 2022 7:47 pm

Hi everyone,

Recently when I implemented scaling process and the corresponding IK process(using the static data and scaled model), a weired phenomenon appeared, that their reported error are not the same. For example, the scaling max marker error is 0.0125m while the IK max marker error is 0.00423m, however, the are from the same marker. Have you met this problem before and do you know why this difference exists?

Thank you so much for your reading!

Sincerely,
Chiho Ng
2022.7.28