Provide easy-to-use, extensible software for modeling, simulating, controlling, and analyzing the neuromusculoskeletal system.
-
Zakia Hussain
- Posts: 37
- Joined: Sun Dec 26, 2021 10:44 pm
Post
by Zakia Hussain » Thu May 25, 2023 8:59 pm
Hi everyone
I am using OpenSim 3.3. When i do the IK analysis, the model appears to be shaking which also results in rough IK plot like
Also it only happens when i use this model
https://simtk.org/frs/?group_id=933
Although its filtered during ID but what can be the possible reason?
Thank you
Regards
Zakia
-
Attachments
-
![Screenshot 2023-05-26 115817.png](./download/file.php?id=6825&sid=4d83d0ba18e41dd09adf307d2a6b136d)
- Screenshot 2023-05-26 115817.png (52.16 KiB) Viewed 377 times
Tags:
-
Luca Modenese
- Posts: 43
- Joined: Wed Jan 21, 2009 9:16 am
Post
by Luca Modenese » Fri May 26, 2023 8:31 am
Hello Zakia,
if I remember correctly sometimes the accuracy value could cause that. I would try changing
to something like
in the IK setup file.
I hope this helps,
Luca
-
Zakia Hussain
- Posts: 37
- Joined: Sun Dec 26, 2021 10:44 pm
Post
by Zakia Hussain » Fri May 26, 2023 6:14 pm
Hi Luca
Thanks for responding
This worked and improved the IK results significantly.
Thanks again
Best regards
Zakia