RRA model sinks into ground

Provide easy-to-use, extensible software for modeling, simulating, controlling, and analyzing the neuromusculoskeletal system.
POST REPLY
User avatar
Aya Alwan
Posts: 8
Joined: Tue Jun 02, 2020 9:21 am

RRA model sinks into ground

Post by Aya Alwan » Sat Jul 13, 2024 1:50 pm

Hello,

I'm using Opensim 4.5 to run RRA and CMC on a walking trial. The model sinks into the ground as if GRF data don't exist. I'm attaching the GRF, IK, and model files. I use the default actuators, constraints, and tasks files from gait2354 model. Could you help resolve the issue? I tried the recommendations from previous posts and it still falls into the ground. I would highly appreciate it if someone could check my GRF file.

Thank you,

Aya
Attachments
temp_RRA_GRF_filtered.xml
(2.63 KiB) Downloaded 51 times
Trial016-IK-Results-stride01.mot
(48.64 KiB) Downloaded 48 times
Filtered_GRF-016_normalWalk01_stride01.mot
(13.58 KiB) Downloaded 56 times
gait2354_simbody_scaled_probed_Trial016.osim
(433.98 KiB) Downloaded 52 times

Tags:

User avatar
Mohammadreza Rezaie
Posts: 407
Joined: Fri Nov 24, 2017 12:48 am

Re: RRA model sinks into ground

Post by Mohammadreza Rezaie » Sun Jul 14, 2024 11:09 pm

Hi, looking at your force file, there are two redundant lines after endheader, and you need to remove them.
Screenshot 2024-07-15 093909.jpg
Screenshot 2024-07-15 093909.jpg (38.88 KiB) Viewed 1256 times
Hope this helps.

User avatar
Aya Alwan
Posts: 8
Joined: Tue Jun 02, 2020 9:21 am

Re: RRA model sinks into ground

Post by Aya Alwan » Mon Jul 15, 2024 6:51 am

I did resolve this issue after posting the thread. The original problem is still there. Thank you though!

User avatar
Mohammadreza Rezaie
Posts: 407
Joined: Fri Nov 24, 2017 12:48 am

Re: RRA model sinks into ground

Post by Mohammadreza Rezaie » Mon Jul 15, 2024 11:25 pm

Another issue I just found is that the GRF must be applied to the calcn_r (right side) and calcn_r (left side) bodies rather than the ground. This could be adjusted directly in the XML file or in the GUI:
Screenshot 2024-07-16 095117.jpg
Screenshot 2024-07-16 095117.jpg (73.43 KiB) Viewed 1151 times
Hope this helps.

User avatar
Aya Alwan
Posts: 8
Joined: Tue Jun 02, 2020 9:21 am

Re: RRA model sinks into ground

Post by Aya Alwan » Tue Jul 16, 2024 11:03 am

Hi Mohammadreza,

I must have overlooked that. It helped! Thank you!! In terms of metabolic cost. I get about 500 Joules as a result from the "integrate" operation for the Umberger metabolic probe (CMC results). If I divide the value by duration (0.7 seconds) and weight (63 kg), I get about 11 W/kg. If I take the average metabolic cost results from the "value" operation and I integrate the total metabolic cost offline, I get 6.9 W/kg. Both do not seem to be reasonable values for someone walking on a treadmill at a 0.8 m/s speed. Is there something I'm missing? why does the integrate method in OpenSim provide different results from my offline integration?

Thanks again!

POST REPLY