Differences between revisions 14 and 15
Revision 14 as of 2014-09-22 17:28:14
Size: 4279
Editor: aerdemir
Comment:
Revision 15 as of 2014-09-22 17:35:38
Size: 4917
Editor: aerdemir
Comment:
Deletions are marked like this. Additions are marked like this.
Line 56: Line 56:
  * Ahmet reviewed the MR images of oks004 by downloading separate MRI sequences from the in-house Midas Platform
   * General purpose imaging sequence is noisy.
   * Coronal image sequence for soft tissue reconstruction was not collected. The images are in the sagittal plane.
   * The specimen seems to have bone anomalies in the marrow space.
   * The team needs to check images during imaging to ensure all sequences are right. Craig will follow up with the personnel in the imaging facility about MRI issues of oks004. Ahmet and Craig will follow up with Carl Winalski to understand if the specimen exhibits any bone pathology.

Recurring Meeting of Cleveland Clinic Core Team

Date: September 16, 2014

Time: 10:30 AM EST

Means: In person meeting

Attendees:

  1. Ahmet Erdemir
  2. Craig Bennetts
  3. Snehal Chokhandre
  4. Robb Colbrunn

Agenda:

  1. Discuss immediate action items from the last meeting.
  2. Discuss tissue mechanical testing related issues and progress.
  3. Discuss testing schedule for 4 oks specimens.
  4. Decide immediate action items for the next meeting.
  5. Other.

Immediate Action Items:

  • Ahmet
    • Provide administrator privileges to all team members in data organization staging server (Midas).
  • Ahmet & Tara

    • Review tissue testing specifications page.
  • Snehal
    • Incorporate notes on tissue testing directly in the wiki page.
    • In tissue testing specifications, provide file type and the resolution of video data collection.
    • Get off-the-shelf registration marker spheres tapped for experiments.
    • Talk to Morgan Jones about scheduling of tissue dissection.
    • Update oks005 page to provide information on recently delivered specimen.
  • Craig
    • Follow up with CASE Imaging facility about MRI issues (noisy general purpose imaging, missing coronal image set for connective tissue imaging).
  • Ahmet & Craig

    • Follow up with Carl Winalski about the potential bone problems notice in MR images of oks004.
  • Snehal & Robb

    • Provide dimensions for registration marker screws to Ahmet (to eventually design new registration markers).

Notes:

  1. Discuss immediate action items from the last meeting.
    • Martin Garon from Biomomentum Inc. has been visiting to resolve data acquisition issues during tissue testing. Snehal, Robb, and Ahmet already had discussions with him. Martin was able to reproduce the issues in our machine. Martin has a few ideas on why the use of the camera may cause system crash and potential solutions: RAID configuration of hard-drives, collection of images in low resolution with RAW format, avoiding writing files to the desktop, turning of indexing for file search, avoiding writing too many files in the same folder, etc. Ahmet was previously collecting data at high resolution (1280x960, BMP or RAW). The spikes in displacement data is probably due to video capture.
    • Craig converted Open Knee(s) - Generation 1 model to make it compatible with FEBio version 2. Ahmet ran some simulations using multiple cores in the in-house high performance computing architecture resulting in significant reduction in computational cost, e.g., 1 hour when using 16 cores. Craig and Ahmet have been discussing scripting for this model as well as upcoming Generation 2 models. Two sets of scripts may need to be developed; one for cloud computing to modify the models, another for assembly of models.
    • Ahmet evaluated user privileges for data organization using the in house Midas Platform. Members of a community can only view the files. Moderators can upload files, create folders. Administrator can move folders including those created by moderators. Ahmet needs to provide all team members administrator privileges to allow them organize the folder structure.
    • Snehal needs to have administrator rights to organize tissue testing data in the Midas Platform. She has ordered an external hard-drive to transfer data from data acquisition system.
    • Discussions on Snehal's activities relevant to tissue mechanical testing can be found in the notes for the following agenda item.
    • Snehal contacted XYZ Scientific to get a quote for Truegrid upgrade. She have not received a response yet.
    • Ahmet reviewed the MR images of oks004 by downloading separate MRI sequences from the in-house Midas Platform
      • General purpose imaging sequence is noisy.
      • Coronal image sequence for soft tissue reconstruction was not collected. The images are in the sagittal plane.
      • The specimen seems to have bone anomalies in the marrow space.
      • The team needs to check images during imaging to ensure all sequences are right. Craig will follow up with the personnel in the imaging facility about MRI issues of oks004. Ahmet and Craig will follow up with Carl Winalski to understand if the specimen exhibits any bone pathology.
  2. Discuss tissue mechanical testing related issues and progress.
    • In the oks004 wiki page, Shenal uploaded a file summarizing tissue testing samples and providing experimentation notes. She will move the contents of the file to the wiki page for others to edit. This will provide hierarchical organization sample information within the specimen page.
  3. Discuss testing schedule for 4 oks specimens.
    • TBD
  4. Decide immediate action items for the next meeting.
    • Action items were discussed and agreed upon. See Immediate Action Items above.
  5. Other.
    • TBD