TableOfContents

Target Outcome

Material behavior for all primary and secondary tissues necessary for required representative constitutive models.

Prerequisites

Infrastructure

For more details see ["Infrastructure/ExperimentationMechanics"].

Previous Protocols

For more details see ["Specifications/Specimens"].

For more details see ["Specifications/ExperimentationAnatomicalImaging"]

For more details see ["Specifications/Registration"].

For more details see ["Specifications/SpecimenPreparation"].

For more details see ["Specifications/ExperimentationJointMechanics"]

Tissue types

Primary tissues

Cartilage

  1. Medial femoral condyle
  2. Lateral femoral condyle
  3. Medial tibial plateau
  4. Lateral tibial plateau
  5. Patellar groove / femoral groove
  6. Patella

Meniscus

  1. Medial meniscus
  2. Lateral meniscus

Ligaments

  1. Anterior collateral ligament
  2. Posterior collateral ligament
  3. Lateral collateral ligament
  4. Medial collateral ligament
  5. Patellar ligament

Tendon

  1. Quadriceps tendon

Secondary tissues

Capsule

  1. TBD

Protocols

Ligaments

Conditions

Measurements

Operating Procedure

Cartilage

Conditions

Measurements

Operating Procedure

Menisci

Conditions

Measurements

Operating Procedure

Tendons

Conditions

Measurements

Operating Procedure

Capsule

Conditions

Measurements

Operating Procedure

References

1. Seitz, Andreas Martin, Fabio Galbusera, Carina Krais, Anita Ignatius, and Lutz Dürselen. “Stress-relaxation Response of Human Menisci Under Confined Compression Conditions.” Journal of the Mechanical Behavior of Biomedical Materials 26 (October 2013): 68–80. doi:10.1016/j.jmbbm.2013.05.027. http://www.sciencedirect.com/science/article/pii/S175161611300204X


-- ["aerdemir"] DateTime(2013-10-15T13:42:41Z) I provided an outline above to help categorize activities.

-- ["aerdemir"] DateTime(2013-10-15T13:42:41Z) Should sample descriptions go to "Specifications/Specimens"? Ideally tissue-specific operating procedure should be followed for any given sample from that tissue.

Sample thickness measurement: Trial 1

Sample

Optical measurement

Using a constant-pressure LVDT probe

Sample1

1.01 mm (0.056)

0.59 mm (0.083)

Sample2

0.83 mm (0.110)

1.04 mm (0.199)

Note For each sample 5 measurements were taken for both methods.