Target Outcome

This specification defines the lumped model that will be used as a test problem within Febio, which will prove useful when comparing different contact formulations within Febio and between different software versions.

Protocols

Required Infrastructure

Input

Fully specific lumped model for specimen 008's upper leg, for details on the modeling steps refer to our specifications on fully Fully Specific Modeling.

Models

The unmeshed model components and the meshed model components are located within the repository. Links for each model component are included below:

  1. Unmeshed Components
    1. Unmeshed Flesh

    2. Unmeshed Bone

  2. Meshed Components
    1. Meshed Flesh

    2. Meshed Probe

    3. Meshed Bone

  3. Febio version 2.5 Input Files
    1. Febio Geometry File

    2. Febio Input File

  4. Febio version 2.5 Output Files
    1. Log File

    2. Postview File

  5. Febio version 2.8 Input Files
    1. Febio 2.8 Geometry File

    2. Febio 2.8 Input File with augmented lagrangian method

  6. Febio version 2.8 Output Files
    1. 2.8 Log File

    2. 2.8 Postview File

Specifications/FebioTestSuite (last edited 2018-10-30 15:05:50 by sbdoherty)