Share 
Follow 
AboutDownloadsDocumentsForumsWikiSource CodeIssuesNews
Date:
2010-08-18 04:51
Priority:
5
State:
Closed
Submitted by:
Grace Tang (gwtang)
Assigned to:
Mike Wong (mikewong899)
Summary:
ATOM-TYPE-IS-OTHER is non-zero even when all atoms being looked at have standard PDB naming

Detailed description
FEATURE reads in Amber files (amber*.dat) that assign partial charges as well as condense the atom types. However, the Histidine residue (HIS) is not associated with any Amber information because Amber does not name it HIS. Instead, Amber names it HID, HIE, or HIP depending on the protonation state. As a result, whenever FEATURE see a HIS residue, it goes through the Amber parameter file and finds no match. This means whatever properties relying on the Amber file get default values. ATOM-TYPE-IS-OTHER is the default for ATOM-TYPE-IS. Additional properties affected should include CHARGE, POS-CHARGE, NEG-CHARGE and maybe others. I believe the code separately handles the RESIDUE-NAME-IS property, so HIS still gets mapped to RESIDUE-NAME-IS-HIS.

The above explanation is incomplete as non-zero ATOM-TYPE-IS-OTHER is also observed in sites without Histidine. However, I do believe that Histidine is the bulk culprit.

Please see the attached files for more detail. The example provided has ATOM-TYPE-IS-OTHER problems with Histidine and something else.

Add A Comment: Notepad

Message  ↓
Date: 2010-09-07 22:10
Sender: Mike Wong

Merging with bug report ID #1316

https://simtk.org/tracker/index.php?func=detail&aid=1316&group_id=16&atid=145

Attachments:
Size Name Date By Download
111 KiB1FAQ.18.Frame0.zip2010-08-18 04:51gwtang1FAQ.18.Frame0.zip
Field Old Value Date By
status_idOpen2010-09-07 22:10mikewong899
close_date2010-09-07 22:102010-09-07 22:10mikewong899
artifact_group_id1002010-08-18 16:38mikewong899
priority42010-08-18 16:38mikewong899
assigned_tonone2010-08-18 16:38mikewong899
File Added318: 1FAQ.18.Frame0.zip2010-08-18 04:51gwtang